Installation, Maintenance and Commissioning Manual :6877419 02/2013

Electrical Data – W2W2 Continued

SC25D080-W2W2

SC25D090-W2W2

SC25D100-W2W2

Standard Dry Cooler Match

2 x DR55

2 x DR70

2 x DR70

Unit Data Full Function – W2W2

(1)

Nominal Run Amps

A

93.1

95.2

103.3

Maximum Start Amps

A

179.9

174.3

216.4

Recommended Mains Fuse Size

A

125

125

125

Max Mains Incoming Cable Size

mm²

70

70

70

Mains Supply

V

400V / 3PH + N / 50Hz

Control circuit

VAC

24

24

24

Unit Data Cooling Only – W2W2

Nominal Run Amps

A

76.9

79

87.2

Maximum Start Amps

A

163.7

158.1

200.2

Recommended Mains Fuse Size

A

100

100

100

Evaporator Fan Motor – Per Fan

Motor Type

AC

AC

AC

Quantity x Motor Size

(2)

kW

3 x 2.38

3 x 2.38

3 x 2.38

Full Load Amps

A

5

5

5

Locked Rotor Amps

A

17.5

17.5

17.5

Compressor – Compressor 1 , Circuit 1 & 2

(3)

Motor Size

kW

6.31

7.19

7.19

Nominal Run Amps

A

13.3

12.9

12.9

Locked Rotor Amps

A

100

92

92

Type of Start

Direct On Line

Compressor – Compressor 2, Circuit 1 & 2

(3)

Motor Size

kW

6.31

7.19

9.46

Nominal Run Amps

A

13.3

12.9

16.9

Locked Rotor Amps

A

100

92

130

Type of Start

Direct On Line

Standard Dry Cooler Match – AC Motor Per Fan

Quantity x Motor Size

kW

3 x 0.6

4 x 0.6

4 x 0.6

Full Load Amps

A

2.62

2.62

2.62

OPTIONAL EXTRAS

Electric Heating

Stage of Reheat

2

3

2

Number of Elements

6

9

6

Rating (Total)

kW

21

31.5

21

Current Per Phase

A

30.31

30.31

45.47

Humidifier

Capacity

kg/hr

15

15

15

Rating

kW

11.25

11.25

11.25

Full Load Amps

A

16.2

16.2

16.2

Standard Size Fan Motor – EC Motor – Per Fan

Quantity x Motor Size

kW

3 x 2.2

3 x 2.2

3 x 2.2

Full Load Amps

A

3.3

3.3

3.3

Locked Rotor Amps

A

3.3

3.3

3.3

Larger Size Motor – EC Motor – Per Fan

Quantity x Motor Size

kW

3 x 3.1

3 x 3.1

3 x 3.1

Full Load Amps

A

4.8

4.8

4.8

Locked Rotor Amps

A

4.8

4.8

4.8

Standard Condenser Match – EC Motor-Per Fan

Quantity x Motor Size

kW

3 x 0.73

4 x 0.73

4 x 0.73

Full Load Amps

A

3.3

3.3

3.3

SCAF Condenser Match – Motor- Per Fan

Quantity x Motor Size

kW

3 x 1.4

4 x 1.4

4 x 4.1

Full Load Amps

A

6

6

6

(1) Values given for full function units with standard selections for heating, humidification, supply air fans and matched condenser