Smartcool, Precision air conditioning, Health and safety – Airedale SmartCool 11-233kW User Manual

Page 6

Advertising
background image


SmartCool

TM

- D

Precision Air Conditioning

6

Precision Air Conditioning

Installation, Maintenance and Commissioning Manual :6877419 02/2013

Health and Safety

IMPORTANT

The information contained in this manual is critical to the correct operation and
maintenance of the unit and should be read by all persons responsible for the installation,
commissioning and maintenance of this Airedale unit.

Safety

The equipment has been designed and manufactured to meet international safety
standards but, like any mechanical/electrical equipment, care must be taken if you are to
obtain the best results.

CAUTION

1

Installation, service and maintenance of Airedale equipment should only be
carried out by technically trained competent personnel.

CAUTION

2

When working with any air conditioning units ensure that the electrical isolator
is switched off prior to servicing or repair work and that there is no power to
any part of the equipment.

3

Also ensure that there are no other power feeds to the unit such as fire alarm
circuits, BMS circuits etc.

4

Electrical installation commissioning and maintenance work on this equipment
should be undertaken by competent and trained personnel in accordance with local
relevant standards and codes of practice.

5

The refrigerant used in this range of products is classified under the COSHH
regulations as an irritant, with set Workplace Exposure Levels (WEL) for
consideration if this plant is installed in confined or poorly ventilated areas.

6

A full hazard data sheet in accordance with COSHH regulations is available should
this be required.

Protective personal
equipment

Airedale recommends that personal protective equipment is used whilst installing,
maintaining and commissioning equipment.

Refrigerant Warning

The Airedale SmartCool uses R410A refrigerant which is a high pressure refrigerant. It
requires careful attention to proper storage and handling procedures.

Use on manifold gauge sets designed for use with R410A refrigerant. Use only refrigerant
recovery units and cylinders designed for high pressure refrigerants.

R410A must only be charged in the liquid state.

The refrigerant must be stored in a clean, dry area away from sunlight. The refrigerant
must never be stored above 50°C.

Manual Handling

Some operations when servicing or maintaining the unit may require additional assistance
with regard to manual handling. This requirement is down to the discretion of the
engineer. Remember do not perform a lift that exceeds your ability.

Environmental Policy

It is our policy to:

·

Take a proactive approach to resolve environmental issues and ensure
compliance with regulatory requirements.

·

Train personnel in sound environmental practices.

·

Pursue opportunities to conserve resources, prevent pollution and eliminate
waste.

·

Manufacture products in a responsible manner with minimum impact on the
environment.

·

Reduce our use of chemicals and minimise their release to the environment.

·

Measure, control and verify environmental performance through internal and
external audits.

·

Continually improve our environmental performance.