Precision air conditioning, Smartcool, Chilled water single circuit – Airedale SmartCool 11-233kW User Manual

Page 143: C000), C 000, Performance data – chilled water – single circuit, Cooling duties

Advertising
background image



Precision Air Conditioning


SmartCool

TM

– D

Precision Air Conditioning

143

Installation, Maintenance and Commissioning Manual :6877419 02/2013

Chilled Water Single Circuit

(C000)

Performance Data – Chilled Water – Single Circuit

Cooling Duties

Water Inlet / Outlet Temperatures

Model

Air On

5°C / 10°C

7°C / 12°C

8°C / 14°C

10°C / 16°C

5.5°C / 14.5°C

Temp (°C)/ %RH

TC

(kW)

SC

(kW)

TC

(kW)

SC

(kW)

TC

(kW)

SC

(kW)

TC

(kW)

SC

(kW)

TC

(kW)

SC

(kW)

SC19D065-C000-0

22 / 50

78.8

61.3

62.6

53.5

47.5

43.9

37.0

37.0

55.4

49.5

24 / 45

88.6

69.9

72.5

62.1

60.1

56.4

46.1

46.1

67.8

59.5

26 / 40

97.4

78.6

81.2

70.8

69.1

65.3

54.7

54.7

78.0

69.0

SC19D075-C000-0

22 / 50

88.9

69.6

70.5

60.7

53.8

50.4

42.0

42.0

62.7

56.4

24 / 45

100.1

79.4

81.7

70.6

67.5

64.1

52.3

52.3

76.4

67.5

26 / 40

110.1

89.4

91.6

80.6

77.8

74.2

62.2

62.2

87.9

78.3

SC19D090-C000-0

22 / 50

103.5

81.6

81.7

71.3

62.8

60.0

49.3

49.3

72.9

66.2

24 / 45

116.7

93.3

94.9

82.9

78.1

75.2

61.2

61.2

88.5

79.2

26 / 40

128.3

105.1

106.6

94.7

86.9

81.5

72.9

72.9

101.7

91.8

SC25D090-C000-0

22 / 50

111.3

87.5

87.8

76.3

66.4

64.2

51.9

51.9

74.0

70.3

24 / 45

125.5

100.0

102.1

88.9

80.2

74.7

65.2

65.2

92.0

83.6

26 / 40

138.2

112.7

114.7

101.5

92.8

86.6

77.9

77.9

107.3

97.6

SC25D100-C000-0

22 / 50

121.6

96.1

95.7

83.7

72.7

71.0

57.1

57.1

81.5

77.4

24 / 45

137.2

109.8

111.4

97.6

87.9

82.8

71.6

71.6

100.5

91.9

26 / 40

151.2

123.8

125.3

111.5

101.7

96.0

85.5

85.5

117.1

107.2

SC25D110-C000-0

22 / 50

131.6

104.4

103.4

91.0

78.7

77.7

62.1

62.1

88.6

84.3

24 / 45

148.7

119.5

120.5

106.2

95.3

90.7

77.8

77.8

108.8

99.9

26 / 40

163.7

134.7

135.5

121.4

110.4

105.4

93.0

93.0

126.4

116.6

SC31D110-C000-0

22 / 50

127.4

98.5

101.7

86.0

81.8

76.7

60.2

60.2

93.7

81.2

24 / 45

143.1

112.3

117.4

99.8

98.3

90.9

74.4

74.4

112.5

96.7

26 / 40

157.0

126.1

131.3

113.7

112.7

105.0

88.2

88.2

128.5

111.7

SC31D130-C000-0

22 / 50

146.8

114.3

116.9

99.8

93.8

88.9

69.8

69.8

107.7

94.2

24 / 45

165.1

130.3

135.2

115.9

112.8

105.5

86.3

86.3

129.1

112.0

26 / 40

181.3

146.5

151.3

132.1

129.3

122.0

102.4

102.4

147.4

129.5

SC31D150-C000-0

22 / 50

165.5

129.6

131.5

113.2

101.1

93.9

79.1

79.1

120.9

106.7

24 / 45

186.3

147.9

152.2

131.6

126.5

119.6

97.8

97.8

144.9

126.8

26 / 40

204.7

166.4

170.5

150.1

145.2

138.5

116.1

116.1

165.4

146.7

TC = Total Cooling, SC =Sensible Cooling
(1) All data quoted is gross

(2) Deduct fan gain for net duties, refer to Mechanical Data
(3) Water Flow rate (l/s)= TC/(4.19 x ∆T) at 100% Water
(4) Refer to Waterside pressure Drop (kPa)

C