Chapter 11: Board Configuration

128

AltiWare ACM 5.1 Administration Manual

Configuration

Double-click the TritonIP board in the Boards window to open the Board Configuration
window, similar to Figure 2 on page 124. See attribute descriptions below Figure 2. Note
the following additional information:

Clicking the Board Configuration button opens a window that displays the board
serial number, DSP clock, and physical and logical IDs. The drop-down list in the
Configure Type field lets you select between a 12-port G.711/G.723/G.729
configuration and a 30-port G.711 configuration.

Figure 5. Board Configuration window

Configuring the Triton T1/E1 Board

Overview of the Triton T1/E1 Board

Through AltiWare Administrator, the Triton T1/E1 board can be configured for either
digital T1 CAS (channel associated signaling), T1 PRI (Primary Rate Interface), E1 CAS,
or E1 PRI.
Both T1 CAS and T1 PRI carry 24 channels using time-division multiplexing (TDM) at an
overall rate of 1.544 Mbps. Voice T1 provides 24 64K channels with robbed bit signaling.
T1 PRI provides 23 64K channels, using one 64K channel for D channel messaging.
E1 CAS and E1 PRI carry 32 channels using TDM at an overall rate of 2.048 Mbps. Both
of them provide 30 64K channels for voice.
To subscribe to T1 CAS, T1 PRI, E1 CAS, or E1 PRI service, you must supply certain
parameters. These parameters are listed in Appendix B on page 419.

Configuring the Board

Double-click the Triton T1/E1 board in the Boards window to open the Board
Configuration
window, similar to Figure 2 on page 124. See attribute descriptions
below Figure 2. Note the following additional information:

The Board ID must be in the range 0–7.

Double-click a channel in the Channel Mapping List to open a trunk configuration
dialog box.

Double-click a channel group to open a configuration window, discussed in the
following section.

Clicking the Board Configuration button opens a configuration dialog box that
displays the board’s serial number, DSP clock, physical and logical IDs.

If you change this configuration,
you must restart the switching
services for the change to take
effect.