Appendix A: E1-R2 and E1 ISDN PRI Installations

404

AltiWare ACM 5.1 Administration Manual

2. In the Board Configuration window, double-click the channel group to open the

Channel Group Configuration dialog box.

Figure 1. Physical Layer

Consult your CO for “Frame Type,” “Line Code,” or “Zero Code Suppression.”
Do not check the System Clock Master check box because the CO is a clock
provider, and the AltiGen system is synchronized to the CO. If all configurations are
correct, the status should be shown as “OK,” as in Figure 1.

3. Click the Protocol button in the Channel Group Configuration dialog box to open the

Protocol Configuration window.

Figure 2. Data Link Layer

4. Select E1 CAS as the Span Type, and select the Switch Mode according to your

country in the E1 R2 Setting field, and click OK.