Required Service Parameters

This appendix identifies the recommended and supported parameters for T1, PRI, and
E1 service and provides you with the information needed when you make your service
request.

Service Parameters/Request Information for T1

To subscribe to T1 service, certain parameters are required to establish service. The
information provided below identifies the recommended and supported parameters for
T1 service. When ordering T1 service, provide the following service request information:

Equipment Information

PBX Manufacturer—AltiGen Communications, Inc.

CSU/DSU—ADTRAN T1 ACE (recommended) or other CSU/DSU

Technical Information for T1 with Voice

Signaling Protocol:

E&M Wink Start (recommended)

E&M Immediate Start

Ground Start

Loop Start (not recommended)

Trunk Type:

DID

2-Way DID (recommended)

DOD

Framing:

Super Frame (SF)/D4

Extended Super Frame (ESF) (recommended)

Line Coding:

Alternate Mark Inversion (AMI)

B8ZS (recommended)