Chapter 14: Out Call Routing Configuration

190

AltiWare ACM 5.1 Administration Manual

Resolving Dialing Delay for Non-USA/Canada

Countries

When installing the AltiGen system outside of North America, you may experience dialing
delay when dialing through E1/PRI trunks that are using en-bloc (buffering digits and
sending all digits at once). The system dialing logic may cause a 7-second inter-digit
dialing delay for en-bloc trunks. To reduce the dialing delay, the following configuration
is recommended:
1. On the Number Plan tab in the System Configuration window, select a digit for

route access.

2. On the Route Definition tab of the Out Call Routing Configuration window, add

a route definition entry for en-bloc and assign the member en-bloc trunk(s).

Advertising