10.3.9 Wrong Cable Warning LED

The main reason for damage to the IVS is incorrectly wired

cables connected to any of the IVS outputs. Even if some

faults do not cause immediate destruction, they put the IVS

at risk and may eventually cause failures of the IVS unit.

Therefore the IVS checks for the following wrong conditions

on the outputs:

• Bridge between camera power supply ground and

video signal ground (e.g. shield of BNC sockets)

• Bridge between positive camera power supply and

video signal ground (e.g. shield of BNC sockets)

• Bridge between positive camera power supply and

housing of the camera and/or IVS

• AC between camera power supply and video signal

ground (e.g. shield of BNC sockets)

• AC between camera power supply and housing of the

camera and/or IVS

• AC between housing of the camera/IVS and video

signal ground (e.g. shield of BNC sockets)

If one of the above described conditions is detected, the

Cable Warning LED (CBL) will light up. Disconnect all cables

form the IVS and/or ARRIFLEX 416 until the warning

disappears. Do not use the faulty cable again.

Note:

The above mentioned faults are caused by 3rd

party cables, improper cables, faulty cables or

a fault condition on equipment connected to

these cables. Please report such conditions

immediately to the camera owner.