Timecode – ARRI ARRIFLEX 416 User Manual

Page 180

Advertising
background image



10

Upper Line 1st Digit for TC Warnings
0 1 2 3 4 5 6 7 8 9 A b C d E F

Warning

Remedy

• • • • • • • •

no valid TC frame rate

set correct TC frame rate

or switch off TC

• • • • • • • •

no meaning on 416

N/A

• • • • • • • •

no meaning on 416

N/A

• • • • • • • •

the last take has no

briefly depress the „PHASE“-button,

or intermittent TC

or reshoot

Upper Line 2nd Digit for TC Warnings
0 1 2 3 4 5 6 7 8 9 A b C d E F

Warning

Remedy

• • • • • • • •

more than 8 hours

reset TC

since TC was last set

• • • • • • • •

TCS values not valid

reset TCS value

• • • • • • • •

ESU frame rate

check ESU frame rate

outside TC range

(display Mode 1)

and TC generator frame rate

(Mode 4);

max. allowable difference is 1 %

• • • • • • • •

no TC with variable speed

switch off variable speed accessory

or TC as TC-operation with variable

speed is not possible

Timecode