1

TC Buffer

The ARRIFLEX 416 ensures not only high accuracy of the

Timecode but also allows the TC clock to continue running

while the camera is switched off as long as the camera is

connected to a power supply. The TC generator needs a

power supply of 10mA when the camera is switched off.

To allow the camera battery to be changed, a short-term

buffer of one minute is provided by charge stored in a

capacitor. In order for this buffer to function however it is

necessary that the camera be connected to a power

supply for at least 10 minutes to allow the capacitor to

charge prior to a battery change. Have a fresh battery

ready before disconnecting the old one.

To enable the camera to be used while mobile without

losing TC time, the use of an on-board battery is

recommended. An on-board battery can power the TC

buffer for more than 100 hours. To reduce power

consumption while working with the battery, the battery

should be removed during lengthy breaks in filming

(longer than a day). Before recommencing filming, TC

synchronization will need to be carried out again.