TC Output

TC information is constantly available as 80bit LTC on the

“TCC“ socket. Output signal is in the LTC format.

From the TC output TC compatible equipment can be

synchronized on the set once (for 8 hours) on the camera’s

Timecode or constantly supplied with Timecode by the

camera. The camera then takes on the master clock function.

The 416 TC Generator is not able to adjust the clock of an

external device to its own clock frequency. When using the

416 TC Generator as a master clock the adaptation to the

master clock has to be done by the slave itself. No

functionality is provided by the 416 in this respect.

Timecode

Timecode and ESU-1

When using the external synchronization unit ESU-1 for

synchronizing the camera to other equipment, Timecode

can still be recorded. The difference between the external

synchronization and the TC frame rate must be less than

1%. If the difference exceeds 1% the TC recording

switches off and the “TC“ symbol in the display goes off.

If the speed comes back to within 1% of the TC frame

rate, TC recording switches on again and the “TC“

symbol appears again on the display. Even if an external

synchronization unit is used, it is necessary to set the

expected frame rate on the camera, before attaching the

ESU-1.