7.4 Attaching the Magazine

• Move the magazine release lever safety catch to the

open position

a

photo

.

• Press down the magazine release lever

a

photo

and

remove the magazine opening cover.

• Remove the loop protector from the magazine.

• Place the magazine’s throat in the camera opening and

slide the magazine forward into the camera until it latches.

• Flip the magazine release lever safety catch forward to

prevent accidental release of the magazine.

• Press the “PHASE” button for a couple of seconds to

inch the film.

Note:

After a new magazine has been attached or after

camera power has been turned on, you should

always push the “PHASE” button to perform a loop

check (the display shows “LooP“). This takes about

2 seconds and will engage the pull down claw,

check loop size and centre the loop properly.

Note:

If the loop check finds that the loop is too short for

safe camera performance the message “Error

LooP.S“ will show in the camera display. The camera

is not ready and will not run. If the loop check

finds that the loop is too long for safe camera

performance the message “Error LooP.L“ will show

in the camera display. The camera is not ready

and will not run.

Camera

Body

release lever

release lever

safety catch

Advertising