Table 10 – CiDRA SONARtrac PW VF-100 User Manual

Page 119

Advertising
background image

20833-01 Rev 04

Page 7-25

Table 10

VF Transmitter Menu Tree Software Release 04.02.XX

Level 1

Level 2

Level 3

Range

Description

Basic Config

Sensor
Serial #

0000000

Serial number of sensor
band

Pipe Size

ID/Wall

ID: 0.1- 100 in (2.54-
2540mm)

Wall 0

– 100 in (0 to

2540 mm)

Pipe inner diameter and
wall thickness

Size/Sched

2 to 36" size; schedule

Pipe size & schedule

OD/Wall

OD: 0.1- 300 in (2.54-
7260mm)

Wall 0

– 100 in (0 to

2540 mm)

Pipe outer diameter and
wall thickness

Fluid
Properties

Liq Spec
Gravity

0 - 999999

Enters the liquid specific
gravity; default water
0.997

Viscosity

0.0000 e-38 to
9.9999 e+38

Enters the liquid
viscosity in Pa-sec;
default water 8.9008e

-4

Calibration
Coefficients

C0 term

0.0000 e-38 to
9.9999 e+38

First term coefficient

C1 term

0.0000 e-38 to
9.9999 e+38

Second term coefficient

C2 term

0.0000 e-38 to
9.9999 e+38

Third term coefficient

Flow
Direction

Forward, Reverse

Sets direction of flow
relative to ‘Flow
Direction’ arrow on
sensor band

Set
Date/Time

MM/DD/YY
HH:MM:SS

Based on Format

Current date/time; Note:
Unit does not adjust for
daylight savings.
Manually adjust as
required.

Set Date
Format

US(MM/DD/YY)
EURO (DD/MM/YY)
ISO8601(YY-MM-DD)

Format of date display
on transmitter