6. Remove the rain seal(s) or boot gasket fenders (stainless steel

covers) from the sensor head (if equipped).

7. Open the sensor cable access panel located on the cover by

loosening the six screws (they should not be fully removed from
the cover as they are captive screws).

8. Disconnect the sensor band to cover electrical connector by

unlatching the connector locks and sliding the connector back as
shown below.

Connector locks

Sensor cable
access port

Sensor
positio

cable with key

ned up (away from

i

)

Figure 1

Sensor Cable Connector Removal

9. Install a sensor band shorting plug on the sensor band cable.

Note: Sensor bands with an “R” in the Part Number suffix (e.g.
Part #: 20686-26-R) do not require a shorting plug.

WARNING

Potential electrical discharge. Always install a sensor band
shorting plug (see item 9 above) on the sensor band connector
whenever the sensor band connector is not installed in a mating
connector. Note: Sensor bands with an “R” in the Part Number
suffix (e.g. Part #: 20686-26-R) do not require a shorting plug.

10. For covers with latches:

a. Refer to Manual Section 5.7.1.3 and install the Sensor Cover

Installation Kit to support the cover during removal from the
process pipe.

b. Remove the lower boot seal clamp or band.

c. Remove the upper boot seal clamp or band.

20837-01 Rev 02

Page 12-2