Table 12 – CiDRA SONARtrac PW VF-100 User Manual

Page 135

Advertising
background image

20833-01 Rev 04

Page 7-41

Table 12

VF/GVF Transmitter Menu Tree Software Release 04.02.XX

Level 1

Level 2

Level 3

Range

Description

Basic Config

Sensor
Serial #

0000000

Serial number of sensor
band

Pipe Size

ID/Wall

ID: 0.1- 100 in (2.54-
2540mm)
Wall 0

– 100 in (0 to

2540 mm)

Pipe inner diameter and
wall thickness

Size/Sched

2 to 36" size;
schedule

Pipe size & schedule

OD/Wall

OD: 0.1- 300 in (2.54-
7260mm)
Wall 0

– 100 in (0 to

2540 mm)

Pipe outer diameter and
wall thickness

Pipe Material

SST, CS, PVC, Custom

Enters the pipe
modulus, kilo-Pascal
(kPa)

Fluid
Properties

Spec Gravity

0 - 999999

Enters the specific
gravity; default water at
25 °C and 14.7 psia

SOS (ft/s)

0 - 999999

Sound speed in media
of interest; ft/sec;
default water at 25 °C
and 14.7 psia

Viscosity

0.0000 e-38 to
9.9999 e+38

Enters the liquid
viscosity in Pa-sec;
default water at 25 °C
and 14.7 psia

Pressure

+/- 0-999999

Process pressure; PSIg,
Barg, kPag

Temperature

-999 to +999C
-1766 to 1830F

Process temperature;
°C or F

Pressure Sel

Fixed, Sensor #1 or #2,
Protocol

Allows for selecting a
fixed pressure input or
using the inputs of
sensor #1 or #2 or using
Modbus input

Temperature
Sel

Fixed, Sensor #1 or #2

Allows for selecting a
fixed temperature input
or using the inputs of
sensor #1 or #2 or using
Modbus input

Altitude

-50,000 to +50,000

Process pipe altitude
above / below sea level;
feet or meter

Calibration

C0 term

0.0000 e-38 to
9.9999 e+38

First term coefficient

C1 term

0.0000 e-38 to
9.9999 e+38

Second term coefficient

C2 term

0.0000 e-38 to
9.9999 e+38

Third term coefficient