20833-01 Rev 04

Page 7-44

Table 12 (page 4) VF/GVF Transmitter Menu Tree Software Release 04.02.XX

Level 1

Level 2

Level 3

Range

Description

Output Config (cont)

Flow & GVF
Damping

State

Enable, Disable

Enable Damping

Time
Constant (s)

0-600 seconds; default
is 3

Smoothes output due to
rapid changes in flow

Flow & GVF
Noise Filter

State

Enable, Disable

Enable noise filtering

Magnitude

Low, High

Amount of damping

VF & GVF
Spike Filter

State

Enable, Disable

Enable spike filtering

No Flow /
GVF Len

1-60

Number of good
measurements during
initialization before VF
(GVF) spike filter
passes measurements
as ‘good’

Length

0

– 60 readings

Defines the number of
consecutive valid
measurements before
displaying flow rate

VF & GVF
Spike Filter
Adv

Up Count

1-60

Number of counts to
INCREMENT the VF
(GVF) Bad Quality
counter when measured
VF (GVF) quality is
below the minimum

Down Count

1-60

Number of counts to
DECREMENT the VF
(GVF) Bad Quality
counter when measured
VF (GVF) quality is
below the minimum

Percent

0

– 100 %

Defines percent
difference of the
previous measurement
over the range below
which the flow rate is
deemed valid

Percent Len

2-60

Number of good
measurements before
VF (GVF) spike filter
passes measurements
as ‘good’