Figure 40, Final alignment and securing of gasket band -36, Figure 41 – CiDRA SONARtrac PW VF-100 User Manual

Page 54: Band termination -36, Figure 42, Stainless steel cover assembly -36

Advertising
background image

20831-01 Rev 05

Page 5-36

Upper cover assembly

Lower cover assembly

Transmitter cable connector
socket

Sensor cable access panel

Cover lifting handles (4 plcs)

Boot Gasket (upper &
lower covers

Tighten the set screw to lock the band in place. The band will be
dimpled by the set screw.

Figure 40 Final Alignment and Securing of Gasket Band

Once the set screw has been fully tightened, loosen the tensioning
tool and bend the tool and band up and over the buckle. It is not
necessary to cut excess band material (allows for re-tightening or re-
use of band if necessary).

Repeat the band installation procedure for the opposite end of the
cover.

Figure 41 Band Termination

The completed stainless cover assembly is shown below

Figure 42 Stainless Steel Cover Assembly

Boot gasket tight against pipe

Buckle over protector plate

Allen wrench tightening
set screw on buckle

Band bent back
over buckle

Advertising