3 display examples, Display examples -18, Figure 15 – CiDRA SONARtrac PW VF-100 User Manual

Page 112: Flow rate is less than minimum configuration -18, Min gal/min

Advertising
background image

20833-01 Rev 04

Page 7-18

Ethernet (E):

Indicates an active Ethernet connection to the transmitter.

Communications:

A symbol here indicates communications activity with the transmitter.
No received serial messages for 10 seconds will clear the activity
indicator.

H - Hart Message Received
M - MODBUS Communications (reverse M indicates write mode)
F - Fieldbus Communications (reverse F indicates write mode)
S - Serial Activity
Blank - No Activity

Write Protect (W):

Indicates configuration changes cannot be made to the transmitter.
Write Protect can be turned on and off by the menu, HART, or
MODBUS. Default is OFF.

Event Log Update (!):

A failure event has been saved in the Event Log, accessible from the
front panel menu. Blank means no change to event log since last
accessed.

Activity (/-\l):

Indicator will cycle during normal system operation

7.6.1.3

Display Examples

The following figure shows an example display when the system is
operating and detects a flow rate that is below the system minimum
flow threshold setting. As seen, a <Min indication is given on the
volumetric flow line and the totalizer value shown on line 2 will not
increase. In addition, a status message will indicate the system
condition.

V

< Min gal/min

F

T

19345 gal

O

T

VF

/

Figure 15

Flow Rate Is Less Than Minimum Configuration

The following figure shows the display when the system is collecting
data to calculate a measurement. The ‘------‘indicates the system is
unable to make a measurement, or an internal parameter was
changed that has caused the system to re-initialize.