20834-01 Rev 04

Page 8-23

8.5

Customize Menu

The Customize menu is used to configure the transmitter to meet user
requirements for local display of measurement parameters.

8.5.1

Display

The display parameters are used to customize the displayed units and
appearance of the display.

8.5.1.1

Line 1 and Line 2

Line 1 and Line 2

set the outputs of the display lines to ‘Totalizer’,

Flow Rate %’, ‘Flow Rate’, ‘True Liquid Flow’, ‘GVF’, ’SOS’, and
Blank’ (depending upon system configuration).

8.5.1.2

Contrast

Contrast is used to adjust the screen appearance due to lighting
conditions. Normally this is set to 170.

8.5.2

Sensor Setup

8.5.2.1

State

State is used to turn indiv

idual sensors ‘On’ or ‘Off’. Normal operating

condition is with all sensors set to ‘On’. Sensors should only be
turned off under the direction of Technical Support Personnel.

8.5.3

Flow Units (Systems with Flow)

8.5.3.1

Volume

The menu selectable units for ‘Volume’ are ‘gal’ (gallons), ‘l’ (liters),
m

3

‘,

(cubic meters), ‘user’ (user defined), ‘iga’ (imperial gallons), ‘ft

3

(cubic feet), ‘ft’ (feet), ‘m’ (meter).

8.5.3.2

Time

The menu selectable units for ‘Time’ are ‘s’ (second), ‘m’ (minute), ‘h
(hour), ‘d’ (day), ‘user’ (user defined).
In both the ‘Volume’ and ‘Time’ selections custom user labels can be
input by the user by selecting ‘user’ from the menu. The user defined
labels are then input using the ‘User Volume / Time’, ‘Base’, and
Scale Factors’.

8.5.4

SOS Units (Systems with GVF)

The menu selectable SOS Units are ‘ft’ (feet) and ‘m’ (meter). The
units of time measure are fixed to be in seconds. Hence, the output of
SOS is in units of ‘ft/s’ or ‘m/s’.