WARNING

EXPLOSION HAZARD - Use of power tools for installation may or
may not be acceptable for use in hazardous areas. Review the
terms of the hot work permit prior to use.

5.4

Sensor Installation Guidelines

The following are general installation guidelines and recommendations
for installing a passive sonar meter sensor.

If the installation location is in a hazardous (classified) area, get a
Hot Work Permit prior to installation of system.

Select locations with well-developed flow profiles.

Avoid installation locations directly after piping configurations that
cause flow jetting.

Install flow sensor upstream of control valves, “T”’s, orifice plates,
and any other severe source of flow disturbance.

Locate the sensor upstream of pipe taps such as those used for
temperature and pressure sensors.

Good piping practices are required near flanges. This includes
good alignment of pipes, and properly sized and installed gaskets
that do not disturb the flow profile.

Table 2 lists the recommended installation distances from flow
disturbances. These recommendations apply to flow measurement
installations.

Feature

Upstream

pipe

diameters

Downstream

pipe

diameters

90 Degree Elbow

15

5

Double Elbow in plane

25

5

Double Elbow out of plane

40

5

Diffuser (expansion)

30

5

Reducer

15

5

Control Valve

40

10

Flange

2

2

Table 3

Recommended Distances From Flow Disturbances

Note: The distances from flow disturbances are guidelines only. In
most cases the volumetric flow meter will provide accurate flow
measurements at distances within these guidelines.