4 sensor band thermal barrier installation, Sensor band thermal barrier installation -19, Figure 14 – CiDRA SONARtrac PW VF-100 User Manual

Page 37: Thermal barrier installation over sensor band -19

Advertising
background image

20831-01 Rev 05

Page 5-19

5.6.4

Sensor Band Thermal Barrier Installation

Install the sensor band thermal barrier if one was included with the
System. Refer to the figure below.

1. Align the slit on the thermal barrier with the sensor band to pre-

amplifier cable.

2. Wrap the thermal barrier over the sensor attachment rails.

3. Continue to wrap the thermal barrier around the sensor band.

4. Seal at the Velcro strips and install the straps through the D-rings

on the thermal barrier.

5. Retain the sensor band to pre-amplifier cable in the Velcro

retention loop.

Figure 14 Thermal Barrier Installation Over Sensor Band

Mounting rails on top of
pipe covered with
thermal barrier

Velcro strip for sealing
thermal barrier

Sensor band to pre-
amplifier cable in slot on
thermal barrier

Sensor band to pre-
amplifier cable in
retention loop

Thermal barrier
straps (both sides)