5–38

Programming

[Fault Mask]

This parameter controls which adapters can reset a
fault.

Parameter Number

100

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Sync Mask]

This parameter controls and chooses which
adapters can select the Sync function.

Parameter Number

101

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Traverse Mask]

This parameter controls and chooses which
adapters can select the Traverse function.

Parameter Number

190

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Logic Mask]

Determines which adapters can control the drive. If
the bit for an adapter is set to “0,” the adapter will
have no control functions except for stop. In addi-
tion, the adapter can be removed from the drive
while power is applied without causing a serial fault.

Parameter Number

92

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Local Mask]

This parameter controls which adapters are allowed
to take exclusive control of drive logic commands
(except stop). Exclusive “local” control can only be
taken while the drive is stopped.

Parameter Number

93

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Alarm Mask]

Controls which alarm conditions will
activate the alarm contact (refer to
Chapter 2 – TB2) and set the alarm
bit (bit 6) in [Drive Status].

With a Series A (version 3.0) or
Series B HIM, a Status description
(bit ENUM) is displayed on line 1.

Parameter Number

206

Parameter Type

Read and Write

Bus Charging

Regenerating Current Limit

Regenerating Voltage Limit

Line Loss In Progress

Motor Stalled

Ground Warning

Bit 15

Bit 13 Bit 12 Bit 11 Bit 10 Bit 9

Bit 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Sync Loss

Bit 14

Hardware Current Limit

Motoring Current Limit

Unused

Unused

Voltage Check

Heatsink Temp

Auxiliary Input

4-20 mA Loss

Overcurrent

Masks