Rockwell Automation 1336 8A-48A Fiber Industry User Manual
Page 106
5–40
Programming
[Decel Owner]
This parameter displays which adapter has
exclusive control of selecting [Decel Time 1] or
[Decel Time 2].
Parameter Number
108
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
[Fault Owner]
This parameter displays which adapter is presently
resetting a fault.
Parameter Number
109
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
[Sync Owner]
This parameter displays which adapters have
exclusive control of selecting the Sync function.
Parameter Number
110
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
[Traverse Owner]
This parameter displays which adapters have
exclusive control of selecting the Traverse function.
Parameter Number
191
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
[Local Owner]
This parameter displays which adapter has
requested exclusive control of all drive logic
functions. If an adapter is in local lockout, all other
functions (except stop) on all other adapters are
locked out and non-functional. Local control can only
be obtained when the drive is not running.
Parameter Number
179
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
Owners