5–40

Programming

[Decel Owner]

This parameter displays which adapter has
exclusive control of selecting [Decel Time 1] or
[Decel Time 2].

Parameter Number

108

Parameter Type

Read Only

Units

Display Drive

“0” 0

Non-Owner

“1” 1

Current Owner

[Fault Owner]

This parameter displays which adapter is presently
resetting a fault.

Parameter Number

109

Parameter Type

Read Only

Units

Display Drive

“0” 0

Non-Owner

“1” 1

Current Owner

[Sync Owner]

This parameter displays which adapters have
exclusive control of selecting the Sync function.

Parameter Number

110

Parameter Type

Read Only

Units

Display Drive

“0” 0

Non-Owner

“1” 1

Current Owner

[Traverse Owner]

This parameter displays which adapters have
exclusive control of selecting the Traverse function.

Parameter Number

191

Parameter Type

Read Only

Units

Display Drive

“0” 0

Non-Owner

“1” 1

Current Owner

[Local Owner]

This parameter displays which adapter has
requested exclusive control of all drive logic
functions. If an adapter is in local lockout, all other
functions (except stop) on all other adapters are
locked out and non-functional. Local control can only
be obtained when the drive is not running.

Parameter Number

179

Parameter Type

Read Only

Units

Display Drive

“0” 0

Non-Owner

“1” 1

Current Owner

Owners