3–10

Human Interface Module

Drive –> HIM

(continued)

C. Press Enter. An informational display

will be shown, indicating the drive
type and firmware version.

D. Press Enter to start the upload. The

parameter number currently being
uploaded will be displayed on line 1 of
the HIM. Line 2 will indicate total
progress. Press ESC to stop the upload.

E. “COMPLETE” displayed on line 2

will indicate a successful upload. Press
Enter. If “ERROR” is displayed, see
Chapter 6.

Master Type
Version 2.01

Drive –> HIM 60
|||||

Drive –> HIM 210
COMPLETE

HIM –> Drive

or

or

3. To download a parameter profile from the

HIM to a drive, you must have a Series B
HIM.

Important: The download function will
only be available when there is a valid
profile stored in the HIM.

A. From the EEProm menu (see steps

1A-1C), press the Increment/Decre-
ment keys until “HIM –> Drive” is
displayed.

B. Press the Enter key. A profile name

will be displayed on line 2 of the HIM.
Pressing the Increment/Decrement
keys will scroll the display to a second
profile (if available).

C. Once the desired profile name is

displayed, press the Enter key. An
informational display will be shown,
indicating the version numbers of the
profile and drive.

D. Press Enter to start the download. The

parameter number currently being
downloaded will be displayed on line 1
of the HIM. Line 2 will indicate total
progress. Press ESC to stop the
download.

E. A successful download will be indi-

cated by “COMPLETE” displayed on
line 2 of the HIM. Press Enter. If
“ERROR” is displayed, see Chapter 6.

Master Type
2.01 –> 2.03

EEprom
HIM –> Drive

HIM –> Drive
1 A

HIM –> Drive 60
|||||

Drive –> HIM 210
COMPLETE