Eeprom error, Retries exceeded, Boost error – Rockwell Automation 1336 3-20HP FRN 1.01-3.01 User Manual

Page 100: Negative slope

Advertising
background image

Fault Codes

Chapter 10

10-9

EEPROM Error

Freq

P

R

A fault has been detected originating from the Main Control Board. Check
all wire and cable connections to the Main Control Board. Replace the
Main Control Board if required.

Retries Exceeded

Freq

P

R

The number of drive restart attempts set by Parameter 85 has been
exceeded. The fault must be cleared and the drive manually reset by
cycling power to the drive.

Boost Error

Freq

P

R

An attempt has been made to set Parameter 83 (Run Boost) to a value
greater than Parameter 48 (Start Boost).

Negative Slope

Freq

P

R

Logic has detected a negative slope on the V/Hz curve.
Compare Parameters 18 and 50.

Parameter 18, Base Voltage, must be equal to or greater than Parameter 50,
Break Volts.
Compare Parameters 48 and 50

Parameter 50, Break Volts, must be equal to or greater than Parameter 48,
Start Boost.

Advertising