10 - fault codes, 2 position mode display area, 3 position fault code display area – Rockwell Automation 1336 3-20HP FRN 1.01-3.01 User Manual

Page 92: Special display - enable fault, Special test - input reset, Fault codes

Advertising
background image

10

Chapter

10-1

Fault Codes

Up to 37 fault codes may be displayed for the 1336. In each instance, a
Fault may be reset by cycling power to the drive, or if Parameter 39 is set
to 1, by pressing the Stop pushbutton. Resetting a Fault will not correct the
problem. Corrective action must be taken prior to resetting the fault.

2ĆPosition Mode Display Area

Freq

P

R

The two character P

R

display is not used as part of the fault code display.

However, it may be used to indicate the loss of enable.

3ĆPosition Fault Code Display Area

Freq

P

R

The three character Freq display is used to indicate the fault code acronym.
The fault acronym will be displayed until a drive reset is initiated.

Special Display - Enable Fault

Freq

P

R

The enable interlock is open. The enable interlock is:

Jumper 7-8 of J9 on the Main Control Board if interface option L1, L2, L3
is not installed.

Terminal 30 of TB3 if interface option L1, L2, L3 is installed.

Special Test - Input Reset

Freq

P

R

This is not a fault but a code that is displayed each time the drive is
powered up or when a fault is cleared. It indicates that drive logic is being
reset to initial conditions.

Advertising