Diagnostic current limit, P jump error, Pćjump error – Rockwell Automation 1336 3-20HP FRN 1.01-3.01 User Manual
Page 101
Advertising
Fault Codes
Chapter 10
10-10
Diagnostic Current Limit
Freq
P
R
The drive has reached 150% of rated output current –– The drive’s
hardware current limit while Parameter 82 (Amp Limit Fault Enable) was
on.
PĆJump Error
Freq
P
R
An attempt has been made to enable both P-Jump and Slip Compensation.
Parameters 78-80 are used to program a custom drive output waveform
(a P-jump waveform) for specific applications. Parameter 78
(Traverse Period) will enable Parameters 79 and 80 if set to a value other
than 0.0.
Parameter 42 is used to program slip compensation. Slip compensation is
active whenever Parameter 42 is set to a value other than 0.0 and cannot be
used if a P-jump waveform has been programmed.
Advertising