Specifications

Chapter 4

4-7

Table 4.3 -- B003ĆB200 Output Current and kVA

Internal
Chassis

Component

Heatsink

Heat

Heat

Total

Minimum

Drive

kVA Out

kVA Out

kVA Out

Dissipation

Dissipation

Dissipation

CFM

Amps Out

Rating

380V AC

415V AC

460V AC

(BTU/hour) n

(BTU/hour) n

(BTU/hour) n

Required n

6.0

B003

3.9

4.3

4.8

136

239

375

15

9.6

B005

6.3

6.9

7.6

171

307

477

25

13.0

B007

8.6

9.3

10.4

273

512

784

40

17.0

B010

11.2

12.2

13.5

341

682

1023

53

25.0

B015

16.5

18.0

20.0

443

1023

1466

76

33.0

B020

22.0

24.0

26.0

477

1364

1841

95

41.0

B025

27.0

29.0

33.0

614

1705

2319

120

48.0

B030

32.0

35.0

38.0

716

2046

2762

142

60.0

B040

39.0

43.0

48.0

938

2438

3376

175

75.0

B050

49.0

54.0

60.0

1125

2847

3973

205

120.0

B075

79.0

86.0

96.0

1705

5115

6820

352

150.0

B100

99.0

108.0

120.0

2046

7502

9548

492

180.0

B125

118.0

129.0

143.0

2387

8184

10571

545

218.0

B150

143.0

157.0

174.0

2728

10912

13640

703

290.0

B200

191.0

208.0

231.0

3069

13981

17050

880

Table 4.4 -- C003ĆC200 Output Current and kVA

Internal
Chassis

Component

Heatsink

Heat

Heat

Total

Minimum

Drive

kVA Out

kVA Out

kVA Out

Dissipation

Dissipation

Dissipation

CFM

Amps Out

Rating

500V AC

575V AC

600V AC

(BTU/hour) n

(BTU/hour) n

(BTU/hour) n

Required n

4.3

C003

3.7

4.3

4.3

136

239

375

15

6.7

C005

5.8

6.7

6.7

171

307

477

25

9.9

C007

8.6

9.9

9.9

273

444

717

40

12.1

C010

10.5

12.1

12.1

341

512

853

45

19.0

C015

16.5

18.9

18.9

443

853

1296

60

24.0

C020

20.8

23.9

23.9

477

1023

1500

80

30.0

C025

26.0

29.9

29.9

614

1364

1978

105

35.0

C030

30.3

34.9

34.9

716

1535

2251

115

45.0

C040

39.0

44.8

44.8

938

1876

2814

145

57.0

C050

49.4

56.8

56.8

1125

2217

3342

175

85.0

C075

73.6

84.7

84.7

1705

4433

6138

320

109.0

C100

94.4

108.6

108.6

2046

5797

7843

405

138.0

C125

119.5

137.4

137.4

2387

6820

9207

475

158.0

C150

136.8

157.4

157.4

2728

8525

11253

580

210.0

C200

181.9

209.1

209.1

3069

10571

13640

703

n The above information is provided for reference only. For all ratings the user must verify that the selected enclosure will dissipate the total BTUs

generated within the enclosure without allowing the internal ambient to rise above 50

°

C. Enclosure mounting and location must allow for the heatsink

to extend outside the enclosure.

When locating the drive allow a minimum clearance from other components of 4.0 inches (101.6 mm) on the top and bottom, 2.0 inches (50.8 mm) on

either side.

When mounting the drive, ensure that the heatsink fins are vertical.

With the heatsink exposed to the ambient, the drive will dissipate heat as listed in the Output Current Table above.

Advertising