1.3.14 Display Accumulator

The accumulator must be enabled before use in either

normal mode or setpoint operations. Once enabled,

weight (net weight if a tare is in the system) is

accumulated whenever a print operation is performed

using the

PRINT

key, digital input, or serial command.

The scale must return to zero (net zero if a tare is in the

system) before the next accumulation.

1. Press and hold the

G/N

key for three seconds to

display the accumulated value if accumulator

is enabled.

2. Press the

UP

key to clear the accumulator or

the

PRINT

key to print the accumulator.

Note

The

PRINT key only performs one

accumulation. Weight must return to zero
before another accumulation is allowed.

1.3.15 Count Display Mode

Count mode is entered by pressing the

MODE

(

GROSS/

NET

) key from normal weighing mode when count

mode is enabled. In count display mode, the display

shows the number of parts rather than weight. The

annunciator at the right side of the LCD display reads

piece count (PC). Pressing the

PRINT

key sends the

CFMT print format data string to the serial port.
If a sample weight has not yet been acquired, the

indicator switches automatically to sample acquisition

mode (see Section 6.0 on page 46).

1.3.16 Peak Hold Mode

The peak hold function is used to determine, display,

and print the greatest net weight read during a

weighing cycle.
A weighing cycle ends when the print command is

given, or when the peak net weight is manually cleared

by the

ZERO

or

PRINT

key. Peak hold tracks only net

weight and operates independently of the display. For

example, if the indicator is displaying gross weight, but

AUTO peak hold is active, the display remains in

gross, but the net peak weight is automatically printed

when standstill is achieved at net zero.

Note

Setpoint, time and date, and checkweigh value
changes from weigh mode (press and hold the
UNITS key), accumulator display (press and
hold the
G/N key), keyed tare display (press and
hold the
TARE key), and password entry front
panel entry modes timeout after 10 seconds if
there is no activity.