13

520 Indicator Installation Manual

2.7

Display Board Removal

If you must remove the 520 display board, use the

following procedure:

1. Remove CPU board (see Section 2.6 above).
2. Remove four Phillips head screws in display

board and carefully remove display board.

To replace the display board, reverse the above

procedure. Be sure to reinstall cable ties to secure all

cables inside the indicator enclosure.



+

+



Figure 2-8. VFD Board

2.8

Battery Replacement

The lithium battery on the CPU board maintains the

real-time clock and protects data stored in the system

RAM when the indicator is not connected to AC power.
System RAM data includes prompts and keyboard

locks. This information is lost if the battery loses power

and the indicator is disconnected from AC power. To

prevent loss of data, do the following:

When battery voltage gets low, the indicator

display shows

low bat

. Replace the battery

when this warning is displayed. The battery

should last seven years.

Use the Revolution

®

configuration utility or

EDP commands (see Section 9.1 on page 50)

to store a copy of the indicator configuration

on a PC before attempting battery replacement.

If any data is lost, the indicator configuration

can be restored from the PC.

WARNING

Danger of explosion if battery is
incorrectly replaced. Replace only with
the same or equivalent type
recommended by the manufacturer.
Dispose of unused batteries according to
the manufacturer’s instructions.