Installation

6

2.0

Installation

This section describes procedures for connecting load

cells, digital I/O, and serial communications cables to

the

520

indicator. Instructions for field installation of

the analog output option and replacement of the CPU

board are included, along with assembly drawings and

parts lists for the service technician.

CAUTION

• Use a wrist strap to ground yourself and protect

components from electrostatic discharge (ESD) when
working inside the indicator enclosure.

• This unit uses double pole/neutral fusing which could

create an electric shock hazard. Procedures requiring
work inside the indicator must be performed by qualified
service personnel only.

• The supply cord serves as the power disconnect for the

520

. The power outlet supplying the indicator must be

installed near the unit and be easily accessible.

2.1

Unpacking and Assembly

Immediately after unpacking, visually inspect the

520

to ensure all components are included and undamaged.

The shipping carton should contain the indicator, this

manual, and a parts kit. If any parts were damaged in

shipment, notify Rice Lake Weighing Systems and the

shipper immediately.

2.1.1

Stainless Steel Panel Mount Model Parts
Kit

The following items are found in the stainless steel

panel mount model parts kit:

Capacity label (PN 94422).

Four 8-32NC x 1/4 machine screws (PN

71522).

Seven 10-32NFx machine screws (PN 82425).

One 8-32NC hex kep nut (PN 14626).

One welded clinching bracket (PN 69787).

One 7-position screw terminal (PN 71343)

Two 10-position screw terminals (PN 71344).

One 1/4-28NF slotted, drilled fillister head (PN

42640).

One three-position terminal block (PN 15888).

One stainless steel backing plate (PN 82426).

2.1.2

Desktop Model Parts Kit

The following items are found in the desktop model

parts kit:

Two 8-32NC hex kep nut (PN 14626)

Two No. 8, Type A lock washers (PN 15134)

Two 1/4 x 1/2 x 1/32 nylon washers

(PN 32394)

Two 1/4 - 20, 2-prong black knobs

(PN 68403)

Capacity label (PN 42350)

One 7-position screw terminal (PN 71343)

Two 10-position screw terminals (PN 71344).

2.2

Panel Mount Installation

Use the dimensions shown in Figure 2-1 on page 7 to

lay out the panel cutout for the stainless steel panel

mount enclosure. Use the dimensions shown in

Figure 2-2 on page 7 to lay out the panel cutout for the

desktop model enclosure. See Figure 2-3 on page 8 and

Figure 2-4 on page 8 for enclosure dimensions.

Stainless Steel Panel Mount Installation

Once the cutout has been prepared, slide the enclosure

into the cutout from the front of the panel. Slide the

clinching bracket around the enclosure from inside the

panel. Secure the bracket to the enclosure using the

four 3/16" screws provided in the parts kit (PN 45386),

then use the five 5/8" screws (PN 71523) to secure the

clinching bracket to the panel door.

Desktop Panel Mount Installation

Once the cutout has been prepared, slide the enclosure

into the cutout from the front of the panel. Secure the

clinching brackets to the enclosure, then use the four

screws from the parts kit (PN 78425) to secure the

clinching brackets to the panel door.