Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual
Page 30
Configuration
24
Secondary Units (SECNDR Parameter)
DECPNT
888888.8
8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
Decimal point location. Determines the location of the decimal point or dummy zeroes in the
display.
DSPDIV
5D
1D
2D
Display divisions. Selects the value of minimum division size of the displayed weight.
UNITS
KG
G
OZ
TN
T
GN
LT
NONE
LB
Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; G=gram; OZ=ounce; TN=short ton; T=metric ton; GN=grain; LT=long ton.
MULT
0.453592
Enter other
choices via
keyboard
Multiplier. Specifies the conversion factor by which the primary units are multiplied by to
obtain the secondary units. The default is 0.453592, which is the conversion factor for
changing pounds to kilograms. See Section 12.11 on page 85 for a list of multipliers.
To toggle between primary and secondary units, press the UNITS key.
FORMAT Menu
Parameter
Choices
Description
Table 3-3. Format Menu Parameters (Continued)