Table 11-2 on – Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual

Page 75

Advertising
background image

69

520 Indicator Installation Manual

SETPTS Menu

Parameter

Choices

Description

Level 3 submenus

GROSSSP
NETSP
+RELSP
–RELSP
%RELSP

VALUE
TRIP
BANDVAL
HYSTER
PREACT
PREVAL
RELNUM
BATCH
PSHACCM
PSHTARE
PSHPRNT
ALARM
ACCESS
NAME
DIGOUT

Configure GROSSSP, NETSP, and RELSP setpoints. See Figure 3-12 on page 35
and Level 4 parameter descriptions.

PAUSE
DELAY
WAITSS

PSHTARE
PSHPRNT
PSHACCM
ACCESS
DIGOUT
NAME
VALUE

Configure PAUSE, DELAY, and WAITSS setpoints. See Figure 3-13 on page 36 and
Level 4 parameter descriptions.

COUNTER
AUTOJOG
COZ
INMOTON
INRANGE
–GROSS
–NET
BATCHPR

VALUE
ACCESS
NAME
DIGOUT

Configure COUNTER, AUTOJOG, COZ, INMOTON, INRANGE, –GROSS, –NET,
AND BATCHPR setpoints. See Figure 3-14 on page 36 and Level 4 parameter
descriptions.

TIMER
CONCUR

VALUE
START
END
ACCESS
NAME
DIGOUT

Configure TIMER and CONCUR setpoints. See Figure 3-15 on page 36 and Level 4
parameter descriptions.

Level 4 submenus

VALUE

number

GROSSSP, NETSP, RELSP setpoint types: Specifies the target weight value.

DELAY, AUTOJOG, TIMER, and CONCUR setpoint types: Specifies, in 0.1-second
intervals, a time value in the range 0–65535.

COUNTER setpoint types: Specifies the number of consecutive batches to be run.

TRIP

HIGHER
LOWER
INBAND
OUTBAND

GROSSSP, NETSP, and RELSP setpoint types: Specifies whether the setpoint is
tripped when the weight is higher or lower than the setpoint value, within a band
established around the value, or outside of that band.

In a batch sequence with TRIP=HIGHER, the associated digital output is active until
the setpoint value is reached or exceeded; with TRIP=LOWER, the output is active
until the weight goes below the setpoint value.

BANDVAL

number

GROSSSP, NETSP, and RELSP setpoint types with TRIP=INBAND or OUTBAND:
Specifies a weight equal to half the bandwidth. The band established around the
setpoint value is VALUE ±BANDVAL.

Table 11-2. Setpoint Menu Parameters