5 tare and zero key functions – Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual

Page 81

Advertising
background image

75

520 Indicator Installation Manual

12.5 TARE and ZERO Key Functions

The function of the front panel TARE and ZERO keys depends on the value specified for the REGULAT parameter

on the PROGRM menu. Table 12-4 describes the function of these keys for each of the regulatory modes.

Table 12-4. TARE and ZERO Key Functions for REGULAT Parameter Settings

REGULAT

Parameter Value

Weight on Scale

Tare in System

Front Panel Key Function

TARE

ZERO

NTEP

zero or negative

no

no action

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

TARE

CANADA

zero or negative

no

no action

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

no action

OIML

zero or negative

no

no action

ZERO

yes

CLEAR TARE

ZERO and CLEAR TARE

positive

no

TARE

ZERO

yes

TARE

ZERO and CLEAR TARE if

weight is within ZRANGE.

No action if weight is

outside of ZRANGE

NONE

zero or negative

no

TARE

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

CLEAR TARE

Advertising