Table 9-10. DIG OUT EDP Commands
Command
Description
DON#nn
Set digital output nn on (active)
DON#0
Set all digital outputs on (active)
DOFF#nn
Set digital output nn off (inactive)
DOFF#0
Set all digital outputs off (inactive)
For commands ending with “#nn”, nn is the digital output (1-4) being set on or off.
Table 9-11. DIG IN EDP Commands
Command
Description
Values
DIGIN1
DIGIN2
DIGIN3
Digital input function
OFF, ZERO, NT/GRS, TARE, UNITS, PRINT, ACCUM, DSPTAR,
ENTER, BATRUN, BATSTRT, BATPAUS, KBDLOC, HOLD, CLRCN,
GROSS, NET, PRIM, SEC, TIME, DATE, CLRTAR, CLRACC
Table 9-12. ALGOUT EDP Commands
Command
Description
Values
SOURCE1
Analog output source
GROSS, NET
OFFSET
Zero offset
0%, 20%
ERRACT
Error action
FULLSC, HOLD, ZEROSC
MIN
Minimum value tracked
0–9 999 999
MAX
Maximum value tracked
0–9 999 999
ZERO1
Zero calibration
0–99999
SPAN1
Span calibration
0–99999
EDP Commands