5 ethernet communications, 6 digital i/o, Ethernet communications – Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual

Page 17: Digital i/o, Table 2-4

Advertising
background image

11

520 Indicator Installation Manual

T h e E D P p o r t s u p p o r t s R S - 2 3 2 o r R S - 4 8 5

communications; the printer port provides active 20

mA output and full-duplex RS-232 communications.

Both ports are configured using the SERIAL menu. See

Section 3.0 on page 17 for configuration information.

Table 2-4. J5 Pin Assignments

Connector

Pin

Signal

J5

1

EDP TxD

2

GND

3

EDP RxD

4

Printer TxD

5

Printer RxD

6

–20 mA TxD

7

+20 mA TxD

8

RS-485A

9

RS-485B

10

GND

2.4.5

Ethernet Communications

Communications port J8 on the 520 CPU board is a

special internal connection to the EDP port for RS-232

communications at up to 19200 bps. J8 can be used for

wiring the Ethernet option card (PN 71986) to the

520

indicator.

Table 2-5. J8 Pin Assignments (Ethernet)

Connector

Pin

Signal

J8

1

TXD

2

GND

3

RXD

2.4.6

Digital I/O

Digital inputs can be set to provide many indicator

functions, including all keypad functions. Digital

inputs are active (on) with low voltage (0 VDC),

inactive (off) at 5 VDC. Use the DIG IN menu to

configure the digital inputs.
Digital outputs are typically used to control relays that

drive other equipment. Outputs are designed to sink,

rather than source, switching current. Each output is a

normally open collector circuit, capable of sinking 250

mA when active. Digital outputs are wired to switch

relays when the digital output is active (low, 0 VDC)

with reference to a 5 VDC supply.
Use the SETPTS menu to configure digital outputs.
Table 2-6 shows the pin assignments for connector J4.

Table 2-6. J4 Pin Assignments (Digital I/O)

Connector

Pin

Signal

J4

1

GND

2

DI1

3

DI2

4

DI3

5

DO1

6

DO2

7

DO3

8

DO4

9

GND

10

+5V