5 analog output card installation, 6 cpu board removal – Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual

Page 18

Advertising
background image

Installation

12

2.5

Analog Output Card Installation

To install or replace the analog output option card,

open the

520

enclosure. See Table 2-1 on page 8 for

option card addendum part numbers.
Mount the analog output card on its standoffs in the

location shown in Figure 2-7 on page 12 and plug the

card input into connector J2 on the

520

board. Connect

the output cable to the analog output card as shown in

Table 2-7. Set the mode select jumper for voltage or

current output.

Use the ALGOUT menu to configure the analog output

card when cabling is complete. See Section 12.12 on
page 86 fo
r analog output calibration procedures.

Table 2-7. Analog Output Card Pin Assignments

Pin

Signal

1

+ Current Out

2

– Current Out

3

+ Voltage Out

4

– Voltage Out

.PEF4FMFDU

+VNQFS

7

7

*

*

*

7

Figure 2-7. Analog Output Card Installation

2.6

CPU Board Removal

If you must remove the

520

CPU board, use the

following procedure:

1. Disconnect power to the indicator.
2. Unplug connectors J6 (load cell cable), J5

(serial communications), and J4 (digital I/O).

If an analog output board is installed,

disconnect the analog output cable. See

Figure 2-6 on page 10 for connector locations.

3. Unplug any installed option cards from the

CPU board.

4. Remove brown and blue wire from J3

connector.

5. Unplug ribbon cable from J1.
6. Remove four Phillips head screws located in

each corner of CPU board.

7. Carefully lift CPU board out of enclosure.

To replace the CPU board, reverse the above

procedure. Be sure to reinstall cable ties to secure all

cables inside the indicator enclosure.