12.1 Error Messages

The

520

indicator provides a number of error messages. When an error occurs, the message is shown on the

indicator display. Error conditions can also be checked remotely by using the XE EDP command as described in

Section 12.3 on page 74.

12.1.1 Displayed Error Messages

The

520

provides a number of front panel error messages to assist in problem diagnosis. Table 12-1 lists these

messages and their meanings.

Table 12-1. 520 Error Messages

Error Message

Description

Solution

E EEROM

EEPROM physical error

Call RLWS Service.

E VIREE

Virgin EEPROM

Use TEST menu to perform DEFLT (restore defaults) procedure (see
Section 12.13 on page 86), then recalibrate load cells.

E PCKSM

Parameter checksum error

E LCKSM

Load cell calibration checksum error

Recalibrate load cells.

E ACKSM

A/D calibration checksum error

A/D converter requires recalibration. Call RLWS Service.

E FCKSM

Print format checksum error

Use TEST menu to perform DEFLT (restore defaults) procedure (see
Section 12.13 on page 86).

E IDATA

Internal RAM data error

Call RLWS Service.

E XDATA

External RAM data error

E A/D

A/D physical error

E REF

A/D reference error

A/D converter requires recalibration. Call RLWS Service.

REG ERR

Non-volatile RAM (NVRAM) register
error

Battery weak or not installed. Replace battery, then use TEST menu
to perform CLR NV (clear non-volatile storage) procedure (see
Section 12.13 on page 86).

TAR ERR

Tare register checksum error

Acquire tare, acquire zero, or reset configuration.

ACC ERR

Accumulator overflow error

Press ACCUM to display accumulator value, then press CLEAR
twice to clear the accumulator.

PWRFAIL

Power failure

Input voltage too low.

OVERFL

Overflow error

Weight value too large to be displayed.

------

Gross > overload limit

Gross value exceeds overload limit. Check configuration.

______

A/D underrange

A/D reading < –4 mV. Check scale for binding or damage.

LOW BAT

Low battery

Replace battery.

E GRAV

Gravity error

Do gravity adjustment calibration or check gravity adjustment
settings.

CNT ERR

Count error

Indicator unable to calculate piece weight. Check quantity size on
scale.

OPT ERR

Option board error

Option unable to initialize. Check option board connection or
replace option board.

Advertising