Table 9-8. SETPNTS EDP Commands

Command

Description

Values

SETPOINT

Setpoint number

1–8

KIND

Setpoint kind

OFF, GROSSSP, NETSP, +RELSP, –RELSP, %RELSP, PAUSE,
DELAY, WAITSS, COUNTER, AUTOJOG, COZ, INMOTON,
INRANGE, –GROSS, –NET, BATCHPR, TIMER, CONCUR

VALUE

Setpoint value

number

PSHTARE

Push tare

OFF, ON

PSHPRINT

Push print

OFF, ON, WAITSS

PSHACCM

Push accumulate

OFF, ON, ONQUIET

TRIP

Trip

HIGHER, LOWER, INBAND, OUTBAND

BANDVAL

Band value

number

HYSTER

Hysteresis

number

ALARM

Alarm

OFF, ON

PREACT

Preact

OFF, ON, LEARN, FLOW

PREVAL

Preact value

number

PREADJ

1-100%

PRESTAB

0-65535

PREBAND

number

PRECOUNT

1-65335

BATCH

Batch enable

OFF, ON

BATSTART

Batch step enable

See Section 11.0 on page 65 for detailed information

BATPAUSE

Batch step pause

BATRESET

Batch step reset

BATSTATUS

Batch status

NAME

Setpoint name number

NONE, 1–8

ACCESS

Setpoint access

OFF, ON, HIDE

DIGOUT

Digital output

NONE, 1–4

RELNUM

Relative setpoint number

1–8

START

Starting setpoint

1–8

END

Ending setpoint

1–8

BATCHNG

Batching mode

OFF, AUTO, MANUAL

Table 9-9. PFORMT EDP Commands

Command

Description

Values

GFMT

Gross demand print format string

See Section 10.2 on page 62 for detailed information

NFMT

Net demand print format string

CFMT

Count format string

SPFMT

Setpoint print format string

EDPFMT

EDP demand print format string

HDRFMT

Ticket header format string

STRMFMT

Custom stream format string

55

520 Indicator Installation Manual

Advertising