0 peak hold mode, Peak hold mode – Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual

Page 55

Advertising
background image

49

520 Indicator Installation Manual

8.0

Peak Hold Mode

The peak hold function is used to determine, display,

and print the greatest net weight read during a

weighing cycle.
A weighing cycle ends when the print command is

given, or when the peak net weight is manually cleared

by the

ZERO

and

PRINT

key. Peak hold tracks only net

weight and operates independently of the display. For

example, if the indicator is displaying gross weight, but

AUTO peak hold is active, the display remains in

gross, but the net peak weight is automatically printed

when standstill is achieved at net zero.
Peak hold function is selected using the PK HOLD

parameter on the PROGRM menu (see Section 3.2.5 on

page 30).

Normal Setting

Positive Peak

Manual Reset

This is the basic peak hold function in which a

weight is applied to a scale and the greatest net

weight value is held in memory until the weight

is removed from the scale, and either the

ZERO

or

PRINT

key is pressed. If the display is in gross

mode, the peak net weight can be displayed by

scrolling to the net mode with the

GROSS/NET

key.

Note

A tare weight can be used with peak hold. At
the tare value, the highest peak hold is 0 net.
Tare is cleared by returning to gross zero and
pressing the
TARE key.

Bi-Dir Setting

Bi-Directional Peak

Manual Reset

This is the same as NORMAL parameter setting,

except that the peak can either be a positive or

negative number, determined by the absolute

weight value. This means that if a positive peak

is displayed, a negative weight value of greater

absolute value can update the peak information

in the same cycle. As above, the peak cycle is

reset by pressing the

ZERO

or

PRINT

key after

the weight has been removed.

Auto Setting

Positive Peak

Auto Print

Auto Reset

This is the same as NORMAL parameter setting,

except that automatic print occurs when the

scale load is reduced to 0 ± 10 display divisions

and the scale achieves standstill. Following the

print command, the peak value is cleared and

reset automatically. Press the

ZERO

or

PRINT

key

to clear the peak hold value.
Use the

GROSS/NET

mode key to display gross

weight data during peak hold function cycles.

Advertising