Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual
Page 35
29
520 Indicator Installation Manual
HANDSHK
OFF
ON
Specifies whether XON/XOFF flow control characters are used.
STREAM
OFF
LFT
IND
Specifies whether data is streamed from the printer port and the configuration.
OFF: Data is not streamed from the printer port
LFT (Legal-for-Trade): Data is streamed at the display update rate
IND (Industrial): Data is streamed at the A/D update rate
FORMAT
DEFLT 7
DEFLT 8
CUSTOM
BUS FMT
Specifies whether the serial port sends data using the default stream format (using either 7 or 8
weight digits), a custom stream format (configured in STRMFMT; see Figure 3-10 on page 34), or
is streamed to a network bus (Profibus, Remote I/O, DeviceNet). For more specific information
on CUSTOM stream format, see Table 12-5 on page 77. BUS FMT is only used with serial bus
options.
SERIAL Menu
Parameter
Choices
Description
Table 3-5. Serial Menu Parameters (Continued)