Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual

Page 35

Advertising
background image

29

520 Indicator Installation Manual

HANDSHK

OFF
ON

Specifies whether XON/XOFF flow control characters are used.

STREAM

OFF
LFT
IND

Specifies whether data is streamed from the printer port and the configuration.

OFF: Data is not streamed from the printer port
LFT (Legal-for-Trade): Data is streamed at the display update rate
IND (Industrial): Data is streamed at the A/D update rate

FORMAT

DEFLT 7
DEFLT 8
CUSTOM
BUS FMT

Specifies whether the serial port sends data using the default stream format (using either 7 or 8
weight digits), a custom stream format (configured in STRMFMT; see Figure 3-10 on page 34), or
is streamed to a network bus (Profibus, Remote I/O, DeviceNet). For more specific information
on CUSTOM stream format, see Table 12-5 on page 77. BUS FMT is only used with serial bus
options.

SERIAL Menu

Parameter

Choices

Description

Table 3-5. Serial Menu Parameters (Continued)