3 enclosure disassembly, 4 cable connections, 3 enclosure disassembly 2.4 cable connections – Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual

Page 14

Advertising
background image

7.29

6.22

2.75

7.36

3.88

Installation

8

Figure 2-3. 520 Stainless Steel Panel Mount Dimensions

7.55

.12

3.80

7.27

.50

Figure 2-4. 520 Desktop Dimensions

2.3

Enclosure Disassembly

Enclosure disassembly is not required to make

connections for load cells, serial communications, or

digital I/O. These connectors are all externally

mounted on the back of the indicator.

Stainless Steel Panel Mount Model Disassembly

To remove the enclosure cover of the 520 panel mount

model indicator, loosen and remove four Phillips head

screws on outside of indicator (see Figure 2-9 on

page 15).

Desktop Model Disassembly

To remove the enclosure cover of the 520 desktop

model indicator, loosen and remove four Phillips head

screws on back of indicator. Slide the enclosure off of

the interior tray assembly of the indicator (see

Figure 2-10 on page 16).

WARNING

The

520

has no on/off switch. Before

opening the unit, ensure the power cord is
disconnected from the power outlet.

2.4

Cable Connections

The

520

has three external connectors, a terminal

connector for the power cord (the desktop has inlet

connector), and a cutout for installed options.

Enclosure disassembly is not required to make

connections to load cells, communications, digital

inputs, and digital outputs. These connectors are all

externally mounted on the back of the indicator.
Cable connections for installed options use a cable

assembly with a cover plate over the backplate cutout.

See Table 2-1 for option card addendum part numbers.

Table 2-1. Option Card Addendum

Option

Addendum Part Number

BCD

76127

Remote I/O

69950

DeviceNet

69949

Profibus DP

69948

Ethernet

72117

Advertising