2 front panel display, 3 indicator operations, 1 toggle gross/net mode – Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual

Page 9: 2 toggle units, 3 zero scale, 4 acquire tare, 2 front panel display 1.3 indicator operations, Toggle gross/net mode, Toggle units, Zero scale

Advertising
background image

&/5&3

4".1-&

.0%&

3

520 Indicator Installation Manual

Figure 1-1.

520

Front Panel

1.2

Front Panel Display

Figure 1-1 shows the 520 front panel keys and the key

functions assigned in normal mode.
The 520 display is divided into three areas (see

Figure 1-2):

• The primary display consists of seven large,

14-segment digits used to display weight data.

• A two-digit annunciator shows the units

associated with the displayed value: lb=pounds,

kg=kilograms, oz=ounces, T=short tons, t=metric

tons, LT=long tons, g=grams, GN=grains. The

units can also be set to NONE (no units

information displayed).

The 16-digit secondary display is used to display the

weighing mode (Gross/Brutto or Net), status
indicators, including standstill (

) and center of

zero (

), Bar Graph and Checkweigh.

The symbols shown over the keys in Figure 1-1

(representing up, down, enter, left, right) describe the

key functions assigned in setup mode. In setup mode,

the keys are used to navigate through menus, select

digits within numeric values, and increment/decrement

values. See Section 3.1.3 on page 18 for information

about using the front panel keys in setup mode. In

count mode, the displayed value is PC (Piece Count).

1 3 * . " 3 :  % * 4 1 - ":

4 & $ 0 / % " 3 :  % * 4 1 - ":

%*(*5

"//6/$*"503

GPS6/*54

Figure 1-2.

520

Front Panel Display Areas

1.3

Indicator Operations

Basic 520 operations are summarized below:

1.3.1

Toggle Gross/Net Mode

Press the

GROSS/NET

key to switch the display mode

from gross to net, or from net to gross. If a tare value

has been entered or acquired, the net value is the gross

weight minus the tare. If no tare has been entered or

acquired, the display remains in gross mode.

Gross mode is indicated by the letters

Gr

(or

Br

for

Brutto in OIML mode) on the secondary display; net

mode is indicated by the letters

Nt

.

When piece count mode is enabled, the

GROSS/NET

key toggles between

Gross/Net/Piece Count

.

1.3.2

Toggle Units

Press the

UNITS

key to switch between primary and

secondary units. The units identifier is shown to the

right of the primary display.

1.3.3

Zero Scale

1. In gross mode, remove all weight from the

scale and wait for the standstill annunciator

(

).

2. Press the

ZERO

key. The center of zero (

)

annunciator lights to indicate the scale is

zeroed.

1.3.4

Acquire Tare

1. Place container on scale and wait for the

standstill annunciator (

).