Table 3-7. Setpoint Menu Parameters
SETPTS Menu
Parameter
Choices
Description
Level 2 submenus
SETPT1–SETPT8
OFF
GROSSSP
NETSP
+RELSP
–RELSP
%RELSP
PAUSE
DELAY
WAITSS
COUNTER
AUTOJOG
COZ
INMOTON
INRANGE
–GROSS
–NET
BATCHPR
TIMER
CONCUR
Specifies the setpoint kind.
GROSSSP, NETSP, +RELSP, –RELSP, and %RELSP setpoint kinds can be used as
either batch or continuous setpoints.
PAUSE, DELAY, WAITSS, COUNTER, and AUTOJOG setpoint kinds can only be
used in batch sequences.
COZ, INMOTON, INRANGE, –GROSS, –NET, BATCHPR, TIMER, and CONCUR
setpoint kinds can only be used as continuous setpoints.
See Table 11-1 on page 65 for more information about setpoint kinds.
BATCHNG
OFF
AUTO
MANUAL
Batching enable. Set to AUTO or MANUAL to allow a batch sequence to run.
MANUAL requires a BATSTRT digital input, BATSTART EDP command before the
batch sequence can run. AUTO allows batch sequences to repeat continuously.
Note
37
520 Indicator Installation Manual
See Section 11.0 on page 65 for detailed information on setpoints.