0 configuration, 1 configuration methods, 1 revolution configuration – Rice Lake 520 HMI Digital Weight Indicator Installation Manual User Manual

Page 23: 2 edp command configuration, Configuration, Revolution configuration, Edp command configuration

Advertising
background image

17

520 Indicator Installation Manual

3.0

Configuration

To configure the

520

indicator, the indicator must be

placed in setup mode. The setup switch is accessed by

removing the large fillister head screw on the enclosure

backplate. Switch position is changed by inserting a

screwdriver into the access hole and pressing the

switch.
When the indicator is placed in setup mode, the word

CONFIG

is shown on the display. The CONFIG menu is

the first of ten top-level menus used for configuring the

indicator. Detailed descriptions of these menus are

given in Section 3.2. When configuration is complete,

return to the CONFIG menu and press the (

ZERO

)

key to exit setup mode, then replace the setup switch

access screw.

3.1

Configuration Methods

The

520

indicator can be configured by using the front

panel keys to navigate through a series of configuration

menus or by sending commands or configuration data

to the EDP port. Configuration using the menus is

described in Section 3.1.3.
Configuration using the EDP port can be accomplished

using either the EDP command set described in
Section 9.0 or Version 3.0 or later of the Revolution

®

configuration utility.

3.1.1

Revolution Configuration

The Revolution configuration utility provides the

preferred method for configuring the

520

indicator.

Revolution runs on a personal computer to set

configuration parameters for the indicator (see

S e c t i o n 5 . 0 o n p a g e 4 4 ) . W h e n R e v o l u t i o n

configuration is complete, configuration data is

downloaded to the indicator (see Section 5.3 on

page 45). Figure 3-1 shows an example of one of the

Revolution configuration displays.

Figure 3-1. Sample Revolution Configuration Display

3.1.2

EDP Command Configuration

The EDP command set can be used to configure the

520

indicator using either a personal computer or terminal.

Like Revolution, EDP command configuration sends

commands to the indicator EDP port; unlike

Revolution, EDP commands can be sent using any

external device capable of sending ASCII characters

over a serial connection.
EDP commands duplicate the functions available using

the indicator front panel and provide some functions

not otherwise available. EDP commands can be used to

simulate pressing front panel keys, to configure the

indicator, or to dump lists of parameter settings. See

Section 9.0 on page 50 for more information about

using the EDP command set.

Advertising