Measure the weight of the sample in the air, Submerge only the hanging cage and set to “0, Measure the weight of the sample in water – Rice Lake TA Series, Rice Lake Weighing Systems User Manual

Page 32: Displaying specific gravity, Return to weight display

Advertising
background image

28 RL-TA Series Operation Manual

4.

Measure the weight of the sample in the air.

Put a sample in a cage or on a pan, and measure the weight

of the sample in air. After the weight display is stable,
press the Target key to enter the weight. Then, []

blinks in the display for a few seconds and the measured
weight is displayed. When the weight is entered, [] is

displayed in the lower left of the display.



5.

Submerge only the hanging cage and set to “0”.

Before the measurement in water, submerge only the cage
and press the Zero/Tare key.

This is for removing any residual error due to the hanging

cage.

* Pressing the Print key interrupts the measurement.





6.

Measure the weight of the sample in water.

Put the sample on the hanging cage and submerge the entire

volume.

Be careful that the cage does not touch the bottom of the

container.
After the weight display is stable, press the Target key to

enter the weight.


7.

Displaying specific gravity

When the weight is saved, the resulting specific gravity will

be displayed.
Pressing the Function key toggles the display between the

specific gravity and volume of the sample.


8.

Return to weight display.
You press the Target key while a specific gravity value is

displayed.

The display returns to showing the sample’s normal weight.



Hints

Measurements with smaller size samples may result in some variations in the measured specific gravity

values. In particular, any sample whose specific gravity is larger tends to show more variation.

Use as large a sample as possible for obtaining more stable measurements.

Advertising