6 setting intervals, 7 span adjustment/test command – Rice Lake TA Series, Rice Lake Weighing Systems User Manual

Page 70

Advertising
background image

66 RL-TA Series Operation Manual

17.4.6 Setting intervals

Command Main Body

Description

Value

Response

first

character

second

character

ASCII code

I

A

49H

41H

Interval time

setup

Interval time

A00: Successful

completion

E01: Command error

E02: Interval time error

Insert a comma between the entries for hours, minutes, and seconds; e.g., IA, hh, mm, ss.

17.4.7 Span adjustment/test command

Command Main Body

Description

Value

Response

first

character

second

character

ASCII code

C

0

43H

30H

Disables Cal key and
command inputs.

*1*2

None

A00: Successful

completion

E01: Command

error

E02: Operation is

disabled.

E03: Cancelled by

operation

E04: Abnormal

completion

C

1

43H

31H

Span adjustment
with built-in weights

*3

C

2

43H

32H

Span test with
built-in weights

*3

C

3

43H

33H

Span adjustment
with external weight

C

4

43H

34H

Span test with
external weight

Advertising