6 status (s2:1 character), 7 output data other than measurement data – Rice Lake TA Series, Rice Lake Weighing Systems User Manual

Page 65

Advertising
background image

RL-TA Series Operation Manual 61

17.3.5 Judgment result when the limit function is enabled (S1: 1 character)

S1

ASCII Code

Description

L

4CH

Too little (LO)

1- or 2-point scale

G

47H

Proper (OK)

H

48H

Too much (HI)

1

31H

Rank 1

3- or 4-point scale

2

32H

Rank 2

3

33H

Rank 3

4

34H

Rank 4

5

35H

Rank 5

T

54H

Cumulative value

Data type

U

55H

Unit weight

(SP)

20H

No judgment result or no data type specified

d

64H

Gross

17.3.6 Status (S2:1 character)

S2

ASCII Code

Description

S

53H

Data stable *

U

55H

Data unstable *

E

45H

Data error (Indicates that data other than S2 is invalid.)

([

o - Err], [u - Err])

(SP)

20H

No status specified

* Data that is independent of whether the weighing condition is stable or not, such as cumulative values

and unit weights, is independent of whether S2 is S or U when it is output.

17.3.7 Output data other than measurement data

The following data is accompanied by our proprietary printer control commands prior to and after the data

when output.

(1) Interval output

When each interval output is started or stopped, a header and a footer are output.

Header

-

’ is output for 15 characters and terminators (CR=0DH, LF=0AH).

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Footer
Two linefeeds are inserted.

(Continued on next page.)

Advertising