6 status (s2:1 character), 7 output data other than measurement data – Rice Lake TA Series, Rice Lake Weighing Systems User Manual
Page 65
RL-TA Series Operation Manual 61
17.3.5 Judgment result when the limit function is enabled (S1: 1 character)
S1
ASCII Code
Description
L
4CH
Too little (LO)
1- or 2-point scale
G
47H
Proper (OK)
H
48H
Too much (HI)
1
31H
Rank 1
3- or 4-point scale
2
32H
Rank 2
3
33H
Rank 3
4
34H
Rank 4
5
35H
Rank 5
T
54H
Cumulative value
Data type
U
55H
Unit weight
(SP)
20H
No judgment result or no data type specified
d
64H
Gross
17.3.6 Status (S2:1 character)
S2
ASCII Code
Description
S
53H
Data stable *
U
55H
Data unstable *
E
45H
Data error (Indicates that data other than S2 is invalid.)
([
o - Err], [u - Err])
(SP)
20H
No status specified
* Data that is independent of whether the weighing condition is stable or not, such as cumulative values
and unit weights, is independent of whether S2 is S or U when it is output.
17.3.7 Output data other than measurement data
The following data is accompanied by our proprietary printer control commands prior to and after the data
when output.
(1) Interval output
When each interval output is started or stopped, a header and a footer are output.
Header
‘
-
’ is output for 15 characters and terminators (CR=0DH, LF=0AH).
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Footer
Two linefeeds are inserted.
(Continued on next page.)