17.5 Special Format Output

17.5.1 Special format 1

This output format is applied when [

7. 1.F. 41] is selected in Function 1.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

P1

SP

D1

D2

D3

D4

D5

D6

D7

D8

SP

U1

U2

U3

CR

LF

S

et

v

a

lue

e

rro

r

S

pac

e

Measurement data (including decimal point)

S

pac

e

Unit

Terminator

P1 (One character): Set value error Polarity plus/zero: [+] (2BH), Minus: [-] (2DH)

SP (One character): Space [ ] (20H)

D1~D8 (Eight character): Measurement data,

numerical value [0 to 9] (30H–39H), and decimal point (2EH)

* Numerical values are right-aligned.

A space (20H) is used when there is no numerical value.

SP (One character): Space [ ] (20H)

U1~U3 (Three character): Unit

Unit

Output

ASCII code

mg

mg

(6DH) (67H) (20H)

g

g



(67H) (20H) (20H)

carat

ct

(63H) (74H) (20H)

ounce

oz

(6FH) (7AH) (20H)

pound

lb

(6CH) (62H) (20H)

troy ounce

ozt

(6FH) (7AH) (74H)

penny weight

dwt

(64H) (77H) (74H)

grain

GN

(47H) (4EH) (20H)

tael(Hong Kong)

tlh

(74H) (6CH) (68H)

tael(SG)

tls

(74H) (6CH) (73H)

tael(Taiwan)

tlt

(74H) (6CH) (74H)

momme

mom

(6DH) (6FH) (6DH)

tola

tol

(74H) (6FH) (6CH)

parts counting

pcs

(70H) (63H) (73H)

percentage weighing

%



(25H) (20H) (20H)

unit converting

#



(23H) (20H) (20H)

* When the output is unstable, a unit (three characters) may be a space (20H).

<CR><LF>: terminator