RL-TA Series Operation Manual 65

17.4.4 Set measurement mode command

Command Main Body

Description

Value

Response

first

character

second

character

ASCII code

M

1

4DH

31H

Set to Mode 1

None

A00: Successful

completion

E01: Command error

E02: (error)

M

2

4DH

32H

Set to Mode 2

M

3

4DH

33H

Set to Mode 3

M

4

4DH

34H

Set to Mode 4

* The measurement mode to be activated by the above mode settings 1 to 4 depends on the weighing mode

currently in use.

Mode

setting

Weighing

machine

Parts counting

Percentage

weighing

Unit converting

Gravi-

meter

Mode 1

Weight
measuring

Weight
measuring

Weight
measuring

Weight
measuring

(Error)

Mode 2

Gross weight

Parts counting

Percent
measuring

Coefficient
multiplying

(Error)

Mode 3

Cumulative
weight

*1

Cumulative
count

*1

Cumulative
percent

*1

Cumulative
sum

*1

(Error)

Mode 4

Display in unit
B

*2

Average unit
weight

(Error)

(Error)

(Error)

*1 Mode 3 (M3) can be specified only when the addition function is to be used. If the addition function is

not enabled, it results in an error.

*2 If a unit is not specified for unit B, the balance is set for the weight measuring mode.

When you specify a mode that is not supported by the current Weighing Mode, an error is returned from
the balance.

17.4.5 Request date or time output command

Command Main Body

Description

Value

Response

first

character

second

character

ASCII code

D

D

44H

44H

Date output request

None

A00: Successful

completion

E01: Command error

D

T

44H

54H

Time output request

(1) Date format

DATE:yyyy.mm.dd(CR)(LF)

English

ヒヅケ:yyyy.mm.dd(CR)(LF) Japanese (Katakana)

(2) Time data

TIME:(SP)(SP)(SP)(SP)(SP)hh:mm(CR)(LF) English
ジコク:(SP)(SP)(SP)(SP)(SP)hh:mm(CR)(LF)

Japanese (Katakana)

Advertising